TENS Silver Electrode
4x6" Butterfly, Blue Foam Backed
Blue Foam Electrode with Multistick Gel for Maximum Reusability
You simply cannot buy a better TENS Unit Electrode!
"Prewired" Reusable Self-Adhering Electrodes
For Electrotherapy Stimulation
- Superior silver-coated electrodes deliver more current with
better distribution accross the entire pad.
- Molded wire connector for reliability and durability.
- Flexible solid-carbon pad for maximum charge delivery and
comfort.
- White Cloth-Mesh backing for comfort and durability.
- US made high-stick Ludlow Gel for up to 15-20 uses.
Questions:
Call Manufacturer at 1-800-201-3958 or Visit: www.leadlok.com
|
Features:
Shown here are the results of a Dispersion Meter Test
An electrical current is passed through each electrode for a
period of 60 seconds. The electrical voltage output is identical
for each electrode. The blue/green color shows the current being
dispersed through the electrodes. Because of Lead-Lok's uniques
manufacturing process, PMI electrodes are able to fully disperse
the electrical current accross the entire surface of the electrode.

We also use copper lead wires with special heads that help promote
greater dispersion and prevent wire pull out. Finally, we use
only the finest gel on the market today for greater reusablity
and superior performance. You simply cannot buy a better
TENS Unit Electrode!
Directions:
- Electrodes do not stick well if any lotion, oil, make-up,
dirt, ect., is left on skin. Wash treatment areas with soap
and water. Rinse thoroughly. Dry completely.
- Connect stimulater cables securely to the electrodes so no
metal is visible.
- When removing electrodes from liner or skin, lift on corner
gently and pull. DO NOT pull by the cables. Doing so may damage
electrodes.
- Adhesive increases when electrodes reach skin temperature.
To increase adhesion further, apply small amount of water and
air dry couple of seconds. If electrodes are extremely dry or
to decrease ashesion, use more water and let air dry for a couple
of hours.
- Adjust stimulator off BEFORE attempting to remove electrodes
from skin.
Warnings:
- Single patient use only.
- DO NOT apply to broken skin.
- Should a skin rash occur, immediatly discontinue use and contact
your clinician.
- DO NOT stimulate while driving or operating machinery.
- DO NOT exceed 0.1 watts.
Other Information:
Gel Maintenance
Clean gel surface after each use by holding under dripping water
for 5-10 seconds, while gently rubbing gel surface with fingertips.
- After cleaning, return electrodes to the liner and store in
package at room temperature.
- Electrode longevitly varies, depending on maintenance, skin
condition, frequentcy of uses, type and site of stimulation.
Effective adhesion may be extended by careful cleaning and storing.
Biomedical Innovations
500 Airport Way.
Sandpoint, Idaho 83864
©2008 Lead-Lok www.leadlok.com |
|